Home /

Could extra oxygen make corneal cross-linking more comfortable?

Could extra oxygen make corneal cross-linking more comfortable?

A note on sources: this article is based on the published abstract of the study. We could not access the full paper this week, so we have only used numbers reported in the abstract.

Cross-linking works by combining riboflavin (vitamin B2) drops with UV light to strengthen the collagen in the cornea. The chemical reaction needs oxygen, and faster “accelerated” protocols may use up oxygen in the cornea more quickly. A randomised trial from Farabi Eye Hospital in Tehran, published in the Journal of Cataract & Refractive Surgery (Mohammadi et al., 2026), tested whether raising the oxygen around the eye during treatment makes a difference to results, and to comfort.

What the researchers did

48 eyes with progressive keratoconus were randomly assigned to one of two groups. Both had the same accelerated epi-off cross-linking (9 mW/cm² UV-A for 10 minutes, 5.4 J/cm²). The difference was the air around the eye:

  • High-oxygen group (24 eyes): treated inside a new oxygen chamber at about 60% oxygen.
  • Control group (24 eyes): treated in normal room air (about 21% oxygen).

Vision, glasses prescription and corneal steepness (keratometry) were measured at the start, one month and twelve months. The depth of the “demarcation line”, a marker of how deep the treatment reached, and the health of the cells lining the back of the cornea were measured at one month. Pain during the procedure was rated on the Wong-Baker FACES scale.

What they found

  • The demarcation line was deeper with high oxygen: 307 ± 14 µm vs 279 ± 23 µm (P < .001).
  • At 12 months, the cornea flattened more in the high-oxygen group, measured by flat and steep keratometry (P = .04 and P = .02).
  • Within the high-oxygen group, flat, steep and maximum keratometry all improved from baseline; in the room-air group only flat keratometry improved.
  • Pain during the procedure was lower with high oxygen: 2.4 ± 0.9 vs 3.4 ± 0.7 on the FACES scale (P = .003).
  • The inner cell layer (endothelium) stayed stable in both groups.

Why oxygen matters in cross-linking

When UV light activates riboflavin in the cornea, the reaction that creates new links between collagen fibres consumes oxygen. Laboratory work suggests that accelerated protocols, which use stronger light for a shorter time, can deplete oxygen in the cornea faster than it is replaced from the air. In theory, that could make the treatment shallower or less effective. Supplying extra oxygen is one way researchers have tried to address this, and this trial is one of the first to test a chamber-based approach in patients.

What do these numbers mean?

The “±” figures show how much results varied between people. A P-value under 0.05 suggests the difference is unlikely to be chance alone. A deeper demarcation line is often taken as a sign of a more effective treatment, but it is an indirect marker. What matters most to patients is whether keratoconus stops progressing over years, and whether vision is stable. This trial wasn't large or long enough to answer that.

The pain finding is interesting. Cross-linking is usually done with numbing drops, but many people find it uncomfortable. A one-point difference on a six-face pain scale is modest, but it may matter to anxious patients.

Is this available in New Zealand?

This is a new device tested at one hospital. It is not standard care, and you should not expect it to be offered routinely. Your corneal surgeon can advise on the cross-linking protocol they use and why.

Where to start: your keratoconus optometrist

Cross-linking is performed by an ophthalmologist, but most people's keratoconus journey starts, and continues, with an optometrist who focuses on keratoconus. That optometrist makes the diagnosis with corneal tomography, documents whether the cornea is changing using sequential corneal maps, refers you to a corneal surgeon at the right moment, and fits and manages specialty contact lenses such as scleral lenses for clear, comfortable vision. If you are not sure where to start, our guide on how to find a keratoconus optometrist in New Zealand explains what to look for.

What the study can't tell us

  • It was small (48 eyes) and from a single centre.
  • Twelve months is too short to know whether keratoconus stays stable longer.
  • Pain was rated by patients who may have known which group they were in; the abstract doesn't say whether patients were masked.
  • The abstract doesn't report the size of the between-group differences in keratometry, or vision results.
  • We have only read the abstract.

Keratoconus care in Hamilton

Before any discussion of cross-linking, the first step is accurate diagnosis and evidence of progression. The optometry team at Rose Optometry, including Jagrut and Jacqueline Rowe, provides corneal mapping, monitoring, referral and scleral lens fitting. Read more about keratoconus care at Rose Optometry, our review of scleral lenses for keratoconus, or book a keratoconus appointment.

Reference

  • Mohammadi A, Dehghani S, Abbas H, Savage D, et al. Enhancing patient comfort in epithelium-off crosslinking: potential of high-oxygen chambers. Journal of Cataract & Refractive Surgery. 2026. PMID 42459153. doi:10.1097/j.jcrs.0000000000002014. (Abstract only.)